Untitled-1
PRODUCTS

Hydrogenic acid resistant pH electrode KSPH 160

FESKS Fisk imported hydrofluoric acid-resistant pH electrode KSPH160 HF, which is suitable for chlorofluoroacid media and fluorine industries

Hydrogenic acid resistant pH electrode KSPH 160
  • Hydrogenic acid resistant pH electrode KSPH 160
0
  • Product Details
  • Product Parameters
  • Attachment Download
  • FESKS The company's KSPH160 HF is a composite electrode(Measurement + Reference)byHydrogenic acid resistant glass, sensitive film resistant to mechanical impact. Suitable for: pH measurement in ionic media containing hydrofluoric acid and fluorine.


     Supporting controller:

    FSPH 3700 Basic Controller

    FSPH5280 Intelligent Controller

     

    Technical parameters

    Measuring range:

    0~14pH

    Temperature range:

    -20~80

    Points distinguish Rate:

    0.01pH

    Essence True Degree:

    ±0.01pH

    Pressure range:

    0~6Bar

    Type of warm tonic:

    Pt1000

    film Electricity Resistance:

    < 250MΩ

    zero Electricity Bit:

    7±0.25pH

    Response time:

    < 30S

    Salt bridge type:

    specialporous ceramic wick

    Reference type:

    Ag/AgCl

    Electrode material:

    Glass

    Electricity Solution Liquid:

    Gel

    Mounting threads:

    PG13.5

    Electrode size:

    ∅12*120mm

    Cable length:

    standard5m

     

    KSPH Series PH/ORP Electrodes selection

    KSPH 130A electrode

    Suitable for general sewage and tap waterpH measurement

    KSPH 130B electrode

    Suitable for heavy metals, pH measurement of organic, high-chlorine, ammonia, and chemical wastewater

    KSPH 155T electrode

    Suitable for desulfurizationpH measurement

    KSPH 160HF electrode

    Suitable for water containing hydrofluoric acid and fluorine ionspH measurement

    KSPH 170G electrode

    Suitable for general high temperature mediapH measurement

    KSPH 170GF electrode

    Suitable for high temperature fermentationpH measurement

    KSPH 170GH electrode

    Suitable for high temperature heavy metals, organic, high chlorine, ammonia water, chemical pH measurement

    KSPH 180D electrode

    Suitable for cryogenic mediapH measurement

    KSPH 185C electrode

    Suitable for pure water,pH measurement of low conductivity water bodies such as RO water

    KSOP 190 electrode

    Suitable for general water treatment and highly polluting wastewaterORP value measurement

     

     

     

     

    Daily repair and maintenance of electrodes:

      1. General contamination: Wash the electrode with water, 0.1 moL/INaOH or 0.1 moL/L HCI for several minutes.

      2. Oil or organic contamination: Wash the electrodes with acetone or ethanol for a few seconds.

      3. Sulfide contamination (black membrane): Wash with a mixture of 10% HCL and saturated thiourea.

    4. Protein contamination (yellowing of diaphragm): Use 10% HCL and saturated gastric protein. Wash the enzyme mixture.

     

    Note: When the tested medium has sulfide pollution or protein pollution on the electrode, it should be dealt with promptly.

     

    Storage of electrodes:

      1. When the electrode is not used for a long time, it should be stored in saturated KCL solution or buffer solution.

      2. The electrode cannot be dried for a long time, and the electrode cannot be stored when a dry medium is attached to the surface. Dry electrodes should be placed in a suitable preservation solution for activation before being used.

      3. The electrode can be activated in buffer at pH4 or in 3M HCl (or saturated KCL).

      4. Electrodes cannot be stored in distilled water.


     

    electrode mounting

    费思克 耐氢氟酸pH电极安装方式示意图

    费思克 耐氢氟酸pH电极 支架安装方式示意图

     

     



    FESKS The company's KSPH160 HF is a composite electrode(Measurement + Reference)byHydrogenic acid resistant glass, sensitive film resistant to mechanical impact. Suitable for: pH measurement in ionic media containing hydrofluoric acid and fluorine.


     Supporting controller:

    FSPH 3700 Basic Controller

    FSPH5280 Intelligent Controller

     

    Technical parameters

    Measuring range:

    0~14pH

    Temperature range:

    -20~80

    Points distinguish Rate:

    0.01pH

    Essence True Degree:

    ±0.01pH

    Pressure range:

    0~6Bar

    Type of warm tonic:

    Pt1000

    film Electricity Resistance:

    < 250MΩ

    zero Electricity Bit:

    7±0.25pH

    Response time:

    < 30S

    Salt bridge type:

    specialporous ceramic wick

    Reference type:

    Ag/AgCl

    Electrode material:

    Glass

    Electricity Solution Liquid:

    Gel

    Mounting threads:

    PG13.5

    Electrode size:

    ∅12*120mm

    Cable length:

    standard5m

     

    KSPH Series PH/ORP Electrodes selection

    KSPH 130A electrode

    Suitable for general sewage and tap waterpH measurement

    KSPH 130B electrode

    Suitable for heavy metals, pH measurement of organic, high-chlorine, ammonia, and chemical wastewater

    KSPH 155T electrode

    Suitable for desulfurizationpH measurement

    KSPH 160HF electrode

    Suitable for water containing hydrofluoric acid and fluorine ionspH measurement

    KSPH 170G electrode

    Suitable for general high temperature mediapH measurement

    KSPH 170GF electrode

    Suitable for high temperature fermentationpH measurement

    KSPH 170GH electrode

    Suitable for high temperature heavy metals, organic, high chlorine, ammonia water, chemical pH measurement

    KSPH 180D electrode

    Suitable for cryogenic mediapH measurement

    KSPH 185C electrode

    Suitable for pure water,pH measurement of low conductivity water bodies such as RO water

    KSOP 190 electrode

    Suitable for general water treatment and highly polluting wastewaterORP value measurement

     

     

     

     

    Daily repair and maintenance of electrodes:

      1. General contamination: Wash the electrode with water, 0.1 moL/INaOH or 0.1 moL/L HCI for several minutes.

      2. Oil or organic contamination: Wash the electrodes with acetone or ethanol for a few seconds.

      3. Sulfide contamination (black membrane): Wash with a mixture of 10% HCL and saturated thiourea.

    4. Protein contamination (yellowing of diaphragm): Use 10% HCL and saturated gastric protein. Wash the enzyme mixture.

     

    Note: When the tested medium has sulfide pollution or protein pollution on the electrode, it should be dealt with promptly.

     

    Storage of electrodes:

      1. When the electrode is not used for a long time, it should be stored in saturated KCL solution or buffer solution.

      2. The electrode cannot be dried for a long time, and the electrode cannot be stored when a dry medium is attached to the surface. Dry electrodes should be placed in a suitable preservation solution for activation before being used.

      3. The electrode can be activated in buffer at pH4 or in 3M HCl (or saturated KCL).

      4. Electrodes cannot be stored in distilled water.


     

    electrode mounting

    费思克 耐氢氟酸pH电极安装方式示意图

    费思克 耐氢氟酸pH电极 支架安装方式示意图

     

     



  • No Parameters
  • No Materia
×
图片 2_20250406_17439431063553910