Untitled-1
PRODUCTS

High turbidity SS KSNT 535

The high turbidity SS sensor KSNT535 adopts the principle of 90º scattered light. By directing light from the light source downward into the water sample in the sensor, the light is scattered by suspended particulate matter in the water sample

High turbidity SS KSNT 535
  • High turbidity SS KSNT 535
0
  • Product Details
  • Product Parameters
  • Attachment Download
  • high turbidity/Suspended matter sensor KSNT535 type uses90º scattered lightPrinciple. By guiding the light emitted by the light source downward into the water sample in the sensor, the light is scattered by suspended particulate matter in the water sample, and is equal to the angle of incidence.The 90-degree scattered light is received by a silicon photovoltaic receiver immersed in the water sample, and the turbidity value of the water sample is obtained by calculating the relationship between the 90-degree scattered light and the incident light beam.

     

    Supporting controller:FSTN 5320-H Controller

     

    KSNT 535 Features:

    ◆ 850nm scattering principle is adopted.

    ◆ Use formazine correction to integrate cost-effective optical technology.

    ◆ The sensor can store calibration values and use them for measurement.

    ◆ Excellent anti-corrosion and anti-interference performance

    ◆ Used in urban wastewater treatment, surface water testing, drinking water measurement, etc.

     

    KSNT535 parameters:

    ◆ Measuring range:0.0-1000.0 NTU0.0-4000.0 NTU, 0.0-4500.0mg/L

    ◆ Measurement accuracy: 15% below 20NTU, 5% above 20NTU

    ◆ Temperature range:0-60°℃

    ◆ Maximum data update time:

    ◆ Installation method: bare wire ◆ Electric continuation: standard 7 meters

    ◆ size: medium diameter 27x150mm

    ◆ Maximum pressure:5bars

    ◆ Communication protocol:MobdusRS-485

    ◆ Power supply:12V

    ◆ Material:PVC, DELRIN, Quartz, PMMA, Polyamide

     

    Order description

    Order number

    Model

    Description

    50-5320-20

    FSTU 5320-H

    high turbidity/Suspended matter controller

    22-0535-01

    KSNT 535-1

    0.0-1000.0 NTU Sensor

    22-0535-05

    KSNT 535-5

    0.0-4000.0 NTU Sensor

     


    high turbidity/Suspended matter sensor KSNT535 type uses90º scattered lightPrinciple. By guiding the light emitted by the light source downward into the water sample in the sensor, the light is scattered by suspended particulate matter in the water sample, and is equal to the angle of incidence.The 90-degree scattered light is received by a silicon photovoltaic receiver immersed in the water sample, and the turbidity value of the water sample is obtained by calculating the relationship between the 90-degree scattered light and the incident light beam.

     

    Supporting controller:FSTN 5320-H Controller

     

    KSNT 535 Features:

    ◆ 850nm scattering principle is adopted.

    ◆ Use formazine correction to integrate cost-effective optical technology.

    ◆ The sensor can store calibration values and use them for measurement.

    ◆ Excellent anti-corrosion and anti-interference performance

    ◆ Used in urban wastewater treatment, surface water testing, drinking water measurement, etc.

     

    KSNT535 parameters:

    ◆ Measuring range:0.0-1000.0 NTU0.0-4000.0 NTU, 0.0-4500.0mg/L

    ◆ Measurement accuracy: 15% below 20NTU, 5% above 20NTU

    ◆ Temperature range:0-60°℃

    ◆ Maximum data update time:

    ◆ Installation method: bare wire ◆ Electric continuation: standard 7 meters

    ◆ size: medium diameter 27x150mm

    ◆ Maximum pressure:5bars

    ◆ Communication protocol:MobdusRS-485

    ◆ Power supply:12V

    ◆ Material:PVC, DELRIN, Quartz, PMMA, Polyamide

     

    Order description

    Order number

    Model

    Description

    50-5320-20

    FSTU 5320-H

    high turbidity/Suspended matter controller

    22-0535-01

    KSNT 535-1

    0.0-1000.0 NTU Sensor

    22-0535-05

    KSNT 535-5

    0.0-4000.0 NTU Sensor

     


  • No Parameters
  • No Materia
×
图片 2_20250406_17439431063553910