Untitled-1
PRODUCTS

Economic residual chlorine monitor FSCL 3800

The economical residual chlorine monitor FSCL3800 adopts the principle of constant voltage method and is an analytical equipment for online analysis of residual chlorine in water quality

Economic residual chlorine monitor FSCL 3800
  • Economic residual chlorine monitor FSCL 3800
  • Economic residual chlorine monitor FSCL 3800
  • Economic residual chlorine monitor FSCL 3800
  • Economic residual chlorine monitor FSCL 3800
0 1 2 3
  • Product Details
  • Product Parameters
  • Attachment Download
  • FESKSFiske Water quality online constant voltage methodresidual chlorine monitor FSCL 3800 The model adopts imported microcomputer-type chips and is specially designed for online monitoring of industrial processes. It is an analytical equipment for online analysis of residual chlorine in water quality. It has stable numerical values, simple operation and convenient maintenance. collocationKSCL 528/529 electrodeand flow grooves. It has the characteristics of no need to replace the membrane head, no need to add dissolving solution, convenient maintenance and low cost.

     

    Product characteristics

    ▲ Metallic paint texture process that is resistant to corrosion and stain and easy to clean

    ◆ Imported chip components ensure stable and reliable instrument measurement

    ④ Chinese and English, suitable for all types of people;

    ◆ Large-screen LED-backlit LCD displays measured values, temperature, current and relay status

    ◆ Standard 4~20 mA current output

    ◆ Two sets of independent relays set Hi/Lo alarm points, which are divided into upper and lower limits

    ◆ Support RS485 Modbus RTU standard protocol

    ◆ Manual pH compensation function for more accurate measurement

     

      This controller needs to be connected to KSCL 528/529Sensor is used together

     

     

    Product application

    Products are widely used in drinking water, wastewater treatment, swimming pool water, mineral resorts and other systems, as well as continuous monitoring and control of water quality disinfection processes in power plants, chemical, food, beverage, pharmaceutical, disinfection equipment and other industries.

     

     

    Technical parameters

    Model

    Residual chlorine monitor FSCL 3800

    Function

    CL2 CLO2

    Measuring range

    0.000 - 2.000/0.00-20.00 ppm (mg/L)

    measurement resolution

    0.01 / 0.001 ppm (mg/L)

    measurement accuracy

    ± 0.01 / ± 0.001 ppm (mg/L)

    Temperature compensation method

    Pt-1000/NTC10K

    temperature measurement range

    -10.0 ~ +130.0℃

    temperature compensation range

    -10.0 ~ +130.0℃ (manual/automatic)

    Temperature resolution

    0.1 ℃

    temperature accuracy

    ±0.2℃

    Solution temperature coefficient compensation

    0.01~9.99%

    working environment temperature

    0 ~ +70℃

    storage temperature

    -20 ~ +70℃

    Display

    BeltLED-backlit large dot matrix LCD display

    language selection

    English/Simplified Chinese

    Power source

    90~260VAC,50/60Hz, power consumption

    current output

    isolated4-20mA output, maximum load 500Ω, programmable measurement value

    Current output accuracy

    ±0.05 mA

    Digital output

    RS485 Modbus RTU standard protocol

    communication rate

    9600(fixed)

    alarm output/Contact capacity

    2 sets of independent relays set Hi/Lo alarm points, with hysteresis setting, 5A/250VAC/30VDC

    pH compensation

    manual compensation

    Relay delayed action

    0-120 s

    Protection grade

    IP65

    Instrument/opening size

    108mm*108mm*148mm/92*92mm

    installation method

    Panel mounting/Wall mount installation/Pipeline installation

    weight

    0.55Kg

     

    electrode mounting

     余氯传感器 安装示意图


    Order description

    Model

    Order number

    Description

    FSCL 3800

    30-3800-00

    Basic residual chlorine/Chlorine dioxide controller

    KSCL 528

    22-0528-00

    residual chlorine platinum electrode0.000 - 2.000/0.00-20.00 ppm (mg/L)

    KSCL 529

    22-0529-00

    residual chlorine gold electrode0.000 - 2.000/0.00-20.00 ppm (mg/L)

    FA-223

    20-0223-00

    constant flow channel

     


    FESKSFiske Water quality online constant voltage methodresidual chlorine monitor FSCL 3800 The model adopts imported microcomputer-type chips and is specially designed for online monitoring of industrial processes. It is an analytical equipment for online analysis of residual chlorine in water quality. It has stable numerical values, simple operation and convenient maintenance. collocationKSCL 528/529 electrodeand flow grooves. It has the characteristics of no need to replace the membrane head, no need to add dissolving solution, convenient maintenance and low cost.

     

    Product characteristics

    ▲ Metallic paint texture process that is resistant to corrosion and stain and easy to clean

    ◆ Imported chip components ensure stable and reliable instrument measurement

    ④ Chinese and English, suitable for all types of people;

    ◆ Large-screen LED-backlit LCD displays measured values, temperature, current and relay status

    ◆ Standard 4~20 mA current output

    ◆ Two sets of independent relays set Hi/Lo alarm points, which are divided into upper and lower limits

    ◆ Support RS485 Modbus RTU standard protocol

    ◆ Manual pH compensation function for more accurate measurement

     

      This controller needs to be connected to KSCL 528/529Sensor is used together

     

     

    Product application

    Products are widely used in drinking water, wastewater treatment, swimming pool water, mineral resorts and other systems, as well as continuous monitoring and control of water quality disinfection processes in power plants, chemical, food, beverage, pharmaceutical, disinfection equipment and other industries.

     

     

    Technical parameters

    Model

    Residual chlorine monitor FSCL 3800

    Function

    CL2 CLO2

    Measuring range

    0.000 - 2.000/0.00-20.00 ppm (mg/L)

    measurement resolution

    0.01 / 0.001 ppm (mg/L)

    measurement accuracy

    ± 0.01 / ± 0.001 ppm (mg/L)

    Temperature compensation method

    Pt-1000/NTC10K

    temperature measurement range

    -10.0 ~ +130.0℃

    temperature compensation range

    -10.0 ~ +130.0℃ (manual/automatic)

    Temperature resolution

    0.1 ℃

    temperature accuracy

    ±0.2℃

    Solution temperature coefficient compensation

    0.01~9.99%

    working environment temperature

    0 ~ +70℃

    storage temperature

    -20 ~ +70℃

    Display

    BeltLED-backlit large dot matrix LCD display

    language selection

    English/Simplified Chinese

    Power source

    90~260VAC,50/60Hz, power consumption

    current output

    isolated4-20mA output, maximum load 500Ω, programmable measurement value

    Current output accuracy

    ±0.05 mA

    Digital output

    RS485 Modbus RTU standard protocol

    communication rate

    9600(fixed)

    alarm output/Contact capacity

    2 sets of independent relays set Hi/Lo alarm points, with hysteresis setting, 5A/250VAC/30VDC

    pH compensation

    manual compensation

    Relay delayed action

    0-120 s

    Protection grade

    IP65

    Instrument/opening size

    108mm*108mm*148mm/92*92mm

    installation method

    Panel mounting/Wall mount installation/Pipeline installation

    weight

    0.55Kg

     

    electrode mounting

     余氯传感器 安装示意图


    Order description

    Model

    Order number

    Description

    FSCL 3800

    30-3800-00

    Basic residual chlorine/Chlorine dioxide controller

    KSCL 528

    22-0528-00

    residual chlorine platinum electrode0.000 - 2.000/0.00-20.00 ppm (mg/L)

    KSCL 529

    22-0529-00

    residual chlorine gold electrode0.000 - 2.000/0.00-20.00 ppm (mg/L)

    FA-223

    20-0223-00

    constant flow channel

     


  • No Parameters
  • No Materia
×
图片 2_20250406_17439431063553910