FESKS Online Sludge Concentration FSSS 5330 Type A is based on the combined infrared absorption scattering light method. The infrared light emitted by the light source is scattered by suspended particles in the sample, and is finally converted into electrical signals by a photodetector, and then subjected to analog and digital signal processing to obtain suspended solids in the sample./Sludge concentration value.
Product characteristics
▶ Corrosion-resistant, anti-fouling and easy-to-clean metallic texture process
▶ Imported chip components ensure stable and reliable instrument measurement
▶ infrared absorption scattering light method
▶ PVC electrode with optional cleaning device
▶ BeltLED-backlit large dot matrix LCD display
▶ Automatic identification sensor
▶ 2 channels of 4 - 20 mA current outputs, the corresponding values can be arbitrarily set
▶ One-way multi-function relay, with cleaning, periodic alarm, error alarm functions
▶ Two sets of independent relays set Hi/Lo alarm points, which are divided into upper and lower limits
▶ SupportRS485 Modbus RTU standard protocol
▶ Historical curve, measurement data storage and record query functions (500,000 sets of data)
▶ Various installation methods: disk mounting/Wall mount installation/Pipeline installation
meter application
The product is used in suspended matter in sewage treatment plants and various industrial production processes, water and wastewater treatment processes/Online monitoring of sludge concentration.
☞ This controller needs to be used with a KSSS 550 sensor
Technical parameters(C)
Model | FSSS 5330 | |
Function | Sludge concentration MLSS | suspended solidsSS |
Measuring range | 0.00 – 50.00g/L | 0.0-5000.0mg/L |
measurement resolution | 0.01 | 0.1 |
measurement accuracy | <±5% | ±5% |
Temperature compensation method | NTC | |
temperature measurement range | 0.0 ~ +50.0℃ | |
Temperature resolution | 0.1 ℃ | |
temperature accuracy | ±0.2℃ | |
data update | every time1-60 seconds adjustable | |
working environment temperature | 0 ~ +70℃ | |
storage temperature | -20 ~ +70℃ | |
Display | BeltLED-Backlit Large Dot Matrix LCD | |
Power source | 90 ~ 260VAC, power consumption | |
Sludge concentration current outputone | isolated 4 - 20mA output, maximum load 500Ω | |
Temperature current output2 | isolated 4 - 20mA output, maximum load 500Ω | |
Current output accuracy | ±0.05 mA | |
Digital output | RS485 Modbus RTU standard protocol | |
communication rate | 9600/19200/38400 | |
alarm output/Contact capacity | 2 sets of independent relays set Hi/Lo alarm points, with hysteresis setting, 5A/250VAC/30VDC | |
washing setting | Time:1-1000s; interval: 0.1-1000.0h (time adjustable) | |
One-way multifunctional relay | cleaning/Periodic alarm/False alarm | |
Relay delayed action | 0-120 seconds | |
data recording | Half a million | |
language selection | English/Traditional Chinese/Simplified Chinese | |
USB interface | Record downloads and software updates(Optional) | |
Protection grade | IP65 | |
Instrument size | 144mm*144mm*108mm | |
Opening size | 138*138mm | |
Installation mode | Panel mounting/Wall mount installation/Pipeline installation | |
Weight | 0.85Kg |
Order description
Model | Order number | Description |
FSSS 5330 | 50-5330-00 | Sludge concentration transmitter |
KSSS 550 | 22-0550-00 | Sludge concentration electrode,0.00 – 50.00g/L |
FESKS Online Sludge Concentration FSSS 5330 Type A is based on the combined infrared absorption scattering light method. The infrared light emitted by the light source is scattered by suspended particles in the sample, and is finally converted into electrical signals by a photodetector, and then subjected to analog and digital signal processing to obtain suspended solids in the sample./Sludge concentration value.
Product characteristics
▶ Corrosion-resistant, anti-fouling and easy-to-clean metallic texture process
▶ Imported chip components ensure stable and reliable instrument measurement
▶ infrared absorption scattering light method
▶ PVC electrode with optional cleaning device
▶ BeltLED-backlit large dot matrix LCD display
▶ Automatic identification sensor
▶ 2 channels of 4 - 20 mA current outputs, the corresponding values can be arbitrarily set
▶ One-way multi-function relay, with cleaning, periodic alarm, error alarm functions
▶ Two sets of independent relays set Hi/Lo alarm points, which are divided into upper and lower limits
▶ SupportRS485 Modbus RTU standard protocol
▶ Historical curve, measurement data storage and record query functions (500,000 sets of data)
▶ Various installation methods: disk mounting/Wall mount installation/Pipeline installation
meter application
The product is used in suspended matter in sewage treatment plants and various industrial production processes, water and wastewater treatment processes/Online monitoring of sludge concentration.
☞ This controller needs to be used with a KSSS 550 sensor
Technical parameters(C)
Model | FSSS 5330 | |
Function | Sludge concentration MLSS | suspended solidsSS |
Measuring range | 0.00 – 50.00g/L | 0.0-5000.0mg/L |
measurement resolution | 0.01 | 0.1 |
measurement accuracy | <±5% | ±5% |
Temperature compensation method | NTC | |
temperature measurement range | 0.0 ~ +50.0℃ | |
Temperature resolution | 0.1 ℃ | |
temperature accuracy | ±0.2℃ | |
data update | every time1-60 seconds adjustable | |
working environment temperature | 0 ~ +70℃ | |
storage temperature | -20 ~ +70℃ | |
Display | BeltLED-Backlit Large Dot Matrix LCD | |
Power source | 90 ~ 260VAC, power consumption | |
Sludge concentration current outputone | isolated 4 - 20mA output, maximum load 500Ω | |
Temperature current output2 | isolated 4 - 20mA output, maximum load 500Ω | |
Current output accuracy | ±0.05 mA | |
Digital output | RS485 Modbus RTU standard protocol | |
communication rate | 9600/19200/38400 | |
alarm output/Contact capacity | 2 sets of independent relays set Hi/Lo alarm points, with hysteresis setting, 5A/250VAC/30VDC | |
washing setting | Time:1-1000s; interval: 0.1-1000.0h (time adjustable) | |
One-way multifunctional relay | cleaning/Periodic alarm/False alarm | |
Relay delayed action | 0-120 seconds | |
data recording | Half a million | |
language selection | English/Traditional Chinese/Simplified Chinese | |
USB interface | Record downloads and software updates(Optional) | |
Protection grade | IP65 | |
Instrument size | 144mm*144mm*108mm | |
Opening size | 138*138mm | |
Installation mode | Panel mounting/Wall mount installation/Pipeline installation | |
Weight | 0.85Kg |
Order description
Model | Order number | Description |
FSSS 5330 | 50-5330-00 | Sludge concentration transmitter |
KSSS 550 | 22-0550-00 | Sludge concentration electrode,0.00 – 50.00g/L |